Note 1: Min. 2 clearance required between edge of cutout
and inside back wall of enclosure for gas regulator.
Note 2: Refrigerator installations require ventilation on both sides
of enclosure. Minimum front-to-back inside clearance is 25 3/8.
SPECIAL NOTE: Grill installation into combustible enclosure
requires insulated jacket. Order part #SOL-IRIJ-XX, where XX is the size of the grill in inches.
NATURAL GAS SUPPLY NOTE: A standard 3/8 ID flexible natural gas supply hose has a maximum capacity of 60,000 BTUs and should be used with 27 and 30 grills only. A 1/2 ID natural gas supply hose is required for larger models, or for 30 grills with a side burner. The proper hose is available from Solaire, order part #SOL-12HOSE12.
|
 |
Dimension A
27 Grills 26
30 Grills 28 1/2
42 Grills 40 1/2
56 Grills 54 1/2
IRIJ-27 & 27XL 31 3/8
IRIJ-30 35
IRIJ-42 47
IRIJ-56 61
Dimension B
AGBQ-27 16 1/4
AGBQ-27XL 21
30, 42, 56 Grills 23
IRIJ-27 17 11/16
IRIJ-27XL 22 9/16
IRIJ 30, 42, 56 24 1/2
Dimension C
27 Grills 8 7/8
30, 42, 56 Grills 10 1/4
IRIJ-27 & 27XL 10
IRIJ 30, 42, 56 11 1/4
Dimension D
Door # IRAD-21 18 1/4
Doors # IRAD-30 27 1/4
Doors # IRAD-42 39 1/4
Refrig. # RC42 42 3/8
Dimension E
All Doors 18 1/4
Refrig. # RC42 21 3/8
Dimension F
All Doors 3 7/8
Refrig. # RC42 2 1/8
|